Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 38.432
Filter
1.
Int J Equity Health ; 23(1): 79, 2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38644494

ABSTRACT

BACKGROUND: Water, sanitation, and hygiene (WASH) access is critical to public health and human dignity. People who inject drugs (PWID) experience stigma and structural violence that may limit WASH access. Few studies have assessed WASH access, insecurity, and inequities among PWID. We describe WASH access, social and geographic inequalities, and factors associated with WASH insecurity among PWID in the Tijuana-San Diego metropolitan area. METHODS: In this cross-sectional binational study, we interviewed PWID (age 18+) in 2020-2021 about WASH access and insecurity. City of residence (Tijuana/San Diego) and housing status were considered as independent variables to describe key WASH access outcomes and to assess as factors associated with WASH insecurity outcomes. Measures of association between outcomes and independent variables were assessed using log modified-Poisson regression models adjusting for covariates. RESULTS: Of 586 PWID (202 Tijuana; 384 San Diego), 89% reported basic access to drinking water, 38% had basic hand hygiene, 28% basic sanitation, and 46% access to bathing, and 38% reported recent open defecation. Participants residing in Tijuana reported significantly higher insecurity in accessing basic drinking water (aRR: 1.68, 95%CI: 1.02-2.76), basic hygiene (aRR: 1.45, 95%CI: 1.28-1.64), and bathing (aRR: 1.21, 95%CI: 1.06-1.39) than those living in San Diego. Participants experiencing unsheltered homelessness experienced significantly higher insecurity in accessing basic drinking water (aRR: 2.03, 95%CI: 1.07-3.86), basic sanitation (aRR: 1.68, 95%CI: 1.48, 1.92), bathing (aRR: 1.84, 95%CI: 1.52-2.22), and improved water sources for cleaning wounds (aRR: 3.12, 95%CI: 1.55-6.29) and for preparing drugs (aRR: 2.58, 95%CI: 1.36-4.89) than participants living in permanent housing. CONCLUSION: WASH access among PWID in the Tijuana-San Diego metropolitan area was low by international standards and lower than the national averages in both countries. Homelessness was significantly associated with WASH insecurity in this population. Concentrated efforts are needed to guarantee continuously available WASH services for PWID-especially those who are unsheltered.


Subject(s)
Hygiene , Sanitation , Humans , Cross-Sectional Studies , Sanitation/standards , Sanitation/statistics & numerical data , Female , Male , Adult , Hygiene/standards , California , Substance Abuse, Intravenous/epidemiology , Middle Aged , Mexico , Water Supply/standards , Drinking Water/standards , Young Adult
2.
Bull Environ Contam Toxicol ; 112(5): 67, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38668895

ABSTRACT

To date, there is an increased risk to public health and the environment due to the presence of pharmaceutically active compounds within drinking water supply and distribution networks. Owing to this, a direct injection-HPLC/MS-MS method was developed for the simultaneous determination of 16 active pharmaceutical compounds in tap water samples: amoxicillin, ampicillin, cephalexin, cefotaxime, cefuroxime, ciprofloxacin, clarithromycin, clindamycin, chloramphenicol, cyproterone, erythromycin, flutamide, spironolactone, sulfamethoxazole, tamoxifen, and trimethoprim. Limits of detection (LOD) ranged from 0.2 to 6.0 µg/L while quantification limits (LOQ) from 0.3 to 20 µg/L. Recovery percentages were between 70 and 125%. Total analysis time was short, with all compounds being resolved in less than 2.1 min. Of the 22 tap water samples collected and analyzed, the highest concentrations corresponded to amoxicillin (147 µg/L) and ciprofloxacin (44 µg/L). The findings could set a precedent for establishing safe levels of these compounds and increasing standards for tap water quality in this region.


Subject(s)
Drinking Water , Environmental Monitoring , Tandem Mass Spectrometry , Water Pollutants, Chemical , Water Pollutants, Chemical/analysis , Chromatography, High Pressure Liquid , Drinking Water/chemistry , Environmental Monitoring/methods , Pharmaceutical Preparations/analysis , Limit of Detection , Ciprofloxacin/analysis , Water Supply , Amoxicillin/analysis
3.
Water Sci Technol ; 89(7): 1807-1815, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38619904

ABSTRACT

In our contemporary world, demanding sustainable resource management, the study focuses on innovative fast flow channel designs. It investigates their efficacy in reducing flow kinetic energy, aiming to optimize water and energy management and diminish flood risks. Employing diverse methodologies, it analyzes and develops these designs, proving their substantial impact on stream energy management. These innovations not only enhance energy efficiency but also mitigate risks associated with excess kinetic energy, promoting safer stream management. This research significantly contributes to fluid dynamics and engineering, deepening the understanding of kinetic energy control in flows and offering potential solutions for water supply, environmental sustainability, and infrastructure safety challenges.


Subject(s)
Ecosystem , Water Supply , Floods , Rivers
4.
Water Sci Technol ; 89(7): 1816-1830, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38619905

ABSTRACT

Accurate calculation of flow discharge for sluice gates is essential in irrigation, water supply, and structure safety. The measurement of discharge with the requirement of distinguishing flow regimes is not conducive to application. In this study, a novel approach that considers both free and submerged flow was proposed. The energy-momentum method was employed to derive the coefficient of discharge. Subsequently, the discharge coefficient was determined through the experiment which was performed on the physical model of a vertical sluice gate with a broad-crested weir. Feature engineering, incorporating dimensional analysis, feature construction, and correlation-based selection were performed. The best subset regression method was employed to develop regression equations of the discharge coefficient with the generated features. The derived formula was applied to compute the discharge coefficient in the vertical sluice gate and determine the flow discharge. The accuracy of adopted method was assessed by comparing it with recent studies on submerged flow, and the results demonstrate that the developed approach achieves a high level of accuracy in calculating flow discharge. The coefficient of determination for the calculated flow rate is 0.993, and the root mean square percentage error is 5.04%.


Subject(s)
Water Supply
6.
Arch Environ Contam Toxicol ; 86(3): 288-303, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38568248

ABSTRACT

In this study, the occurrence of phthalates in the municipal water supply of Nagpur City, India, was studied for the first time. The study aimed to provide insights into the extent of phthalate contamination and identify potential sources of contamination in the city's tap water. We analyzed fifteen phthalates and the total concentration (∑15phthalates) ranged from 0.27 to 76.36 µg L-1. Prominent phthalates identified were di-n-butyl phthalate (DBP), di-isobutyl phthalate (DIBP), benzyl butyl phthalate (BBP), di (2-ethylhexyl) phthalate (DEHP), di-n-octyl phthalate (DNOP), and di-nonyl phthalate (DNP). Out of the fifteen phthalates analyzed, DEHP showed the highest concentration in all the samples with the median concentration of 2.27 µg L-1, 1.39 µg L-1, 1.83 µg L-1, 2.02 µg L-1, respectively in Butibori, Gandhibaag, Civil Lines, and Kalmeshwar areas of the city. In 30% of the tap water samples, DEHP was found higher than the EPA maximum contaminant level of 6 µg L-1. The average daily intake (ADI) of phthalates via consumption of tap water was higher for adults (median: 0.25 µg kg-1 day-1) compared to children (median: 0.07 µg kg-1 day-1). The hazard index (HI) calculated for both adults and children was below the threshold level, indicating no significant health risks from chronic toxic risk. However, the maximum carcinogenic risk (CR) for adults (8.44 × 10-3) and children (7.73 × 10-3) was higher than the threshold level. Knowledge of the sources and distribution of phthalate contamination in municipal drinking water is crucial for effective contamination control and management strategies.


Subject(s)
Diethylhexyl Phthalate , Drinking Water , Phthalic Acids , Child , Adult , Humans , Phthalic Acids/analysis , Water Supply , Risk Assessment
7.
J Water Health ; 22(3): 451-466, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38557564

ABSTRACT

The available literature on natural hazard risk analysis focused on the implementation of water safety plans (WSPs) is surprisingly quite poor, despite the significant increase in the number and severity of disasters and adverse effects on drinking water supply systems generated by natural hazards. At the same time, WSPs that conveniently account for natural hazards with a comprehensive approach 'from source to tap' are still scarce as they typically occur at larger spatial scales and adequate prevention, mitigation and adaptation require efficient inter-institutional collaborations. The aim of this paper is to highlight the main bottlenecks for water utilities to include natural hazards in the development of their WSPs. The research adopted a stakeholders-oriented approach, involving a considerable number of water utilities (168), water sectoral agencies (15) and institutions (68) across the Adriatic-Ionian Region through a stepwise process that generated joint SWOT analysis, the development of a decision support system (DSS) focused on WSPs procedures and tabletop exercises. The final outcomes generated strategic documents (REWAS - Adrion Road map for resilient water supply) that highlighted the necessity for efficient cross-sectoral and inter-institutional cooperation in the development of well-founded and robust WSPs to address natural hazard risk analysis for water supply systems (DWSS).


Subject(s)
Drinking Water , Water Supply , Risk Assessment
8.
J Water Health ; 22(3): 550-564, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38557570

ABSTRACT

Onsite wastewater treatment systems (OWTSs) and private wells are commonly used in Eastern North Carolina, USA. Water from private wells is not required to be tested after the initial startup, and thus persons using these wells may experience negative health outcomes if their water is contaminated with waste-related pollutants including bacteria, nitrate or synthetic chemicals such as hexafluoropropylne oxide dimer acid and its ammonium salt (GenX). Water samples from 18 sites with OWTSs and groundwater wells were collected for nitrate, Escherichia coli (E. coli), total coliform, and GenX concentration analyses. Results showed that none of the 18 water supplies were positive for E. coli, nitrate concentrations were all below the maximum contaminant level of 10 mg L-1, and one well had 1 MPN 100 mL-1 of total coliform. However, GenX was detected in wastewater collected from all 18 septic tanks and 22% of the water supplies tested had concentrations that exceeded the health advisory levels for GenX. Water supplies with low concentrations of traditionally tested for pollutants (nitrate, E. coli) may still pose health risks due to elevated concentrations of emerging contaminants like GenX and thus more comprehensive and routine water testing is suggested for this and similar persistent compounds.


Subject(s)
Environmental Pollutants , Groundwater , Water Pollutants, Chemical , Wastewater , Nitrates/analysis , North Carolina , Escherichia coli , Environmental Monitoring/methods , Water Pollutants, Chemical/analysis , Water Supply , Water Wells , Groundwater/microbiology , Organic Chemicals
9.
J Water Health ; 22(3): 510-521, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38557567

ABSTRACT

Anecdotal evidence and available literature indicated that contaminated water played a major role in spreading the prolonged cholera epidemic in Malawi from 2022 to 2023. This study assessed drinking water quality in 17 cholera-affected Malawi districts from February to April 2023. Six hundred and thirty-three records were analysed. The median counts/100 ml for thermotolerant coliform was 98 (interquartile range (IQR): 4-100) and that for Escherichia coli was 0 (IQR: 0-9). The drinking water in all (except one) districts was contaminated by thermotolerant coliform, while six districts had their drinking water sources contaminated by E. coli. The percentage of contaminated drinking water sources was significantly higher in shallow unprotected wells (80.0% for E. coli and 95.0% for thermotolerant coliform) and in households (55.8% for E. coli and 86.0% for thermotolerant coliform). Logistic regression showed that household water has three times more risk of being contaminated by E. coli and two and a half times more risk of being contaminated by thermotolerant coliform compared to other water sources. This study demonstrated widespread contamination of drinking water sources during a cholera epidemic in Malawi, which may be the plausible reason for the protracted nature of the epidemic.


Subject(s)
Cholera , Drinking Water , Humans , Water Supply , Cholera/epidemiology , Cross-Sectional Studies , Escherichia coli , Malawi/epidemiology , Water Microbiology , Water Quality
10.
J Water Health ; 22(3): 612-626, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38557575

ABSTRACT

In a recent monitoring study of Minnesota's public supply wells, Cryptosporidium was commonly detected with 40% of the wells having at least one detection. Risk factors for Cryptosporidium occurrence in drinking water supply wells, beyond surface water influence, remain poorly understood. To address this gap, physical and chemical factors were assessed as potential predictors of Cryptosporidium occurrence in 135 public supply wells in Minnesota. Univariable analysis, regression techniques, and classification trees were used to analyze the data. Many variables were identified as significant risk factors in univariable analysis and several remained significant throughout the succeeding analysis techniques. These factors fell into general categories of well use and construction, aquifer characteristics, and connectedness to the land surface, well capture zones, and land use therein, existence of potential contaminant sources within 200-feet of the well, and variability in the chemical and isotopic parameters measured during the study. These risk categories, and the specific variables and threshold values we have identified, can help guide future research on factors influencing Cryptosporidium contamination of wells and can be used by environmental health programs to develop risk-based sampling plans and design interventions that reduce associated health risks.


Subject(s)
Cryptosporidiosis , Cryptosporidium , Groundwater , Water Pollutants, Chemical , Humans , Cryptosporidiosis/epidemiology , Minnesota , Environmental Monitoring/methods , Water Supply , Water Wells , Risk Factors , Water Pollutants, Chemical/analysis
11.
Sci Rep ; 14(1): 7830, 2024 04 03.
Article in English | MEDLINE | ID: mdl-38570538

ABSTRACT

Groundwater pollution by nitrate has is a major concern in the Tehran-Karaj aquifer, Iran, where the wells provide up to 80% of the water supply for a population of more than 18 million-yet detailed human health risks associated with nitrate are unknown due to the lack of accessible data to adequately cover the aquifer in both place and time. Here, using a rich dataset measured annually in more than 75 wells, we mapped the non-carcinogenic risk of nitrate in the aquifer between 2007 and 2018, a window with the most extensive anthropogenic activities in this region. Nitrate concentration varied from ~ 6 to ~ 150 mg/L, around three times greater than the standard level for drinking use, i.e. 50 mg/L. Samples with a non-carcinogenic risk of nitrate, which mainly located in the eastern parts of the study region, threatened children's health, the most vulnerable age group, in almost all of the years during the study period. Our findings revealed that the number of samples with a positive risk of nitrate for adults decreased in the aquifer from 2007 (17 wells) to 2018 (6 wells). Although we hypothesized that unsustainable agricultural practices, the growing population, and increased industrial activities could have increased the nitrate level in the Tehran-Karaj aquifer, improved sanitation infrastructures helped to prevent the intensification of nitrate pollution in the aquifer during the study period. Our compilation of annually mapped non-carcinogenic risks of nitrate is beneficial for local authorities to understand the high-risk zones in the aquifer and for the formulation of policy actions to protect the human health of people who use groundwater for drinking and other purposes in this densely populated region.


Subject(s)
Groundwater , Water Pollutants, Chemical , Child , Adult , Humans , Nitrates/analysis , Iran , Water Pollutants, Chemical/analysis , Groundwater/chemistry , Water Supply , Environmental Monitoring
13.
Sci Total Environ ; 927: 172410, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38608884

ABSTRACT

There is little evidence of the long-term consequences of maintaining sanitary hot water at high temperatures on the persistence of Legionella in the plumbing system. The aims of this study were to describe the persistence and genotypic variability of L. pneumophila in a hospital building with two entirely independent hot water distribution systems, and to estimate the thermotolerance of the genotypic variants by studying the quantity of VBNC L. pneumophila. Eighty isolates from 55 water samples obtained between the years 2012-2017 were analyzed. All isolates correspond to L. pneumophila serogroup 6. The isolates were discriminated in four restriction patterns by pulsed-field gel electrophoresis. In one installation, pattern A + Aa predominated, accounting for 75.8 % of samples, while the other installation exhibited pattern B as the most frequent (81.8 % of samples; p < 0.001). The mean temperature of the isolates was: 52.6 °C (pattern A + Aa) and 55.0 °C (pattern B), being significantly different. Nine strains were selected as representative among patterns to study their thermotolerance by flow-cytometry after 24 h of thermic treatment. VBNC bacteria were detected in all samples. After thermic treatment at 50 °C, 52.0 % of bacteria had an intact membrane, and after 55 °C this percentage decreased to 23.1 %. Each pattern exhibited varying levels of thermotolerance. These findings indicate that the same hospital building can be colonized with different predominant types of Legionella if it has independent hot water installations. Maintaining a minimum temperature of 50 °C at distal points of the system would allow the survival of replicative L. pneumophila. However, the presence of Legionella in hospital water networks is underestimated if culture is considered as the standard method for Legionella detection, because VBNC do not grow on culture plates. This phenomenon can carry implications for the Legionella risk management plans in hospitals that adjust their control measures based on the microbiological surveillance of water.


Subject(s)
Hospitals , Legionella pneumophila , Water Microbiology , Legionella pneumophila/isolation & purification , Legionella pneumophila/genetics , Legionella pneumophila/physiology , Water Supply , Hot Temperature
14.
Sci Total Environ ; 927: 172257, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38608912

ABSTRACT

Waterborne pathogens threaten 2.2 billion people lacking access to safely managed drinking water services, causing over a million annual diarrheal deaths. Individuals without access to chlorine reagents or filtration devices often resort to do-it-yourself (DIY) methods, such as boiling or solar disinfection (SODIS). However, these methods are not simple to implement. In this study, we introduced an innovative and easily implemented disinfection approach. We discovered that immersing aluminum foil in various alkaline solutions produces alkali-treated aluminum foil (ATA foil) that effectively adsorbs Escherichia coli (E. coli), Salmonella, and Acinetobacter through the generated surface aluminum hydroxide. For example, a 25 cm2 ATA foil efficiently captures all 104E. coli DH5α strains in 100 mL water within 30 min. Using a saturated suspension of magnesium hydroxide, a type of fertilizer, as the alkaline solution, the properties of the saturated suspension eliminate the need for measuring reagents or changing solutions, making it easy for anyone to create ATA foil. ATA foils can be conveniently produced within mesh bags and placed in household water containers, reducing the risk of recontamination. Replacing the ATA foil with a foil improves the adsorption efficiency, and re-immersing the used foil in the production suspension restores its adsorption capacity. Consequently, ATA foil is an accessible and user-friendly alternative DIY method for underserved communities. Verification experiments covering variations in the water quality and climate are crucial for validating the efficacy of the foil. Fortunately, the ATA foil, with DIY characteristics similar to those of boiling and SODIS, is well-suited for testing under diverse global conditions, offering a promising solution for addressing waterborne pathogens worldwide.


Subject(s)
Disinfection , Drinking Water , Water Purification , Drinking Water/microbiology , Drinking Water/chemistry , Disinfection/methods , Water Purification/methods , Water Microbiology , Water Supply
15.
Environ Sci Technol ; 58(15): 6540-6551, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38574283

ABSTRACT

Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.


Subject(s)
Drinking Water , Legionella pneumophila , Legionella , Water Supply , Water Microbiology , Sanitary Engineering , Risk Assessment
16.
J Hazard Mater ; 470: 134229, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38581875

ABSTRACT

Total alpha and beta activities and Rn-222 concentrations were determined in water from different sections of seven aqueducts belonging to the water supply system of Campania region (Italy), known worldwide for its volcanism. Statistical analysis was performed on data to account for their variability across the aqueduct sections, and results were discussed considering the geology of reservoirs, the potential mixing processes occurring along the pipe network, the building/constituting materials of the aqueduct sections, and the integrity of the infrastructure. Guidelines proposed by Italian and international regulation entities were considered to determine if total alpha and beta activities and Rn-222 concentrations found at the taps of the different aqueducts should be considered detrimental to public health. Based on a deterministic and a stochastic approach, a health risk assessment was also tested for Rn-222, assuming direct ingestion and showering as potential exposure pathways. Results showed that applying guidelines returned an absence of hazard, whereas risk assessment returned a high probability of exposure to unacceptable Rn-222 doses for some aqueducts. Beyond the usefulness of obtained results to plan actions to improve the safety of drinking water in Campania, our outcomes represent a warning for bodies dealing with public health at any level: the use of guidelines can bring an underestimation of the risks exerted by the exposure to Rn-222 on human health. Further, using a probabilistic approach in risk assessment accounting for uncertainty can favor risk forecasts based on more "realistic" scenarios.


Subject(s)
Drinking Water , Water Supply , Italy , Humans , Risk Assessment , Drinking Water/analysis , Water Pollutants, Radioactive/analysis , Volcanic Eruptions
17.
Environ Sci Technol ; 58(16): 7010-7019, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38598435

ABSTRACT

Water supply interruptions contribute to household water insecurity. Unpredictable interruptions may particularly exacerbate water insecurity, as uncertainty limits households' ability to optimize water collection and storage or to modify other coping behaviors. This study used regression models of survey data from 2873 households across 10 sites in 9 middle-income countries to assess whether water supply interruptions and the predictability of interruptions were related to composite indicators of stressful behaviors and emotional distress. More frequent water service interruptions were associated with more frequent emotional distress (ß = 0.49, SE = 0.05, P < 0.001) and stressful behaviors (ß = 0.39, SE = 0.06, P < 0.001). Among households that experienced interruptions, predictability mitigated these respective relationships by approximately 25 and 50%. Where the provision of continuous water supplies is challenged by climate change, population growth, and poor management, water service providers may be able to mitigate some psychosocial consequences of intermittency through scheduled intermittency and communication about water supply interruptions. Service providers unable to supply continuous water should optimize intermittent water delivery to reduce negative impacts on users, and global monitoring regimes should account for intermittency and predictability in post-2030 water service metrics to better reflect household water insecurity experiences.


Subject(s)
Water Supply , Humans , Emotions , Family Characteristics , Water Insecurity
18.
Environ Monit Assess ; 196(5): 438, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38592580

ABSTRACT

Advanced sensor technology, especially those that incorporate artificial intelligence (AI), has been recognized as increasingly important in various contemporary applications, including navigation, automation, water under imaging, environmental monitoring, and robotics. Data-driven decision-making and higher efficiency have enabled more excellent infrastructure thanks to integrating AI with sensors. The agricultural sector is one such area that has seen significant promise from this technology using the Internet of Things (IoT) capabilities. This paper describes an intelligent system for monitoring and analyzing agricultural environmental conditions, including weather, soil, and crop health, that uses internet-connected sensors and equipment. This work makes two significant contributions. It first makes it possible to use sensors linked to the IoT to accurately monitor the environment remotely. Gathering and analyzing data over time may give us valuable insights into daily fluctuations and long-term patterns. The second benefit of AI integration is the remote control; it provides for essential activities like irrigation, pest management, and disease detection. The technology can optimize water usage by tracking plant development and health and adjusting watering schedules accordingly. Intelligent Control Systems (Matlab/Simulink Ver. 2022b) use a hybrid controller that combines fuzzy logic with standard PID control to get high-efficiency performance from water pumps. In addition to monitoring crops, smart cameras allow farmers to make real-time adjustments based on soil moisture and plant needs. Potentially revolutionizing contemporary agriculture, this revolutionary approach might boost production, sustainability, and efficiency.


Subject(s)
Artificial Intelligence , Internet of Things , Cloud Computing , Environmental Monitoring , Agriculture , Intelligence , Soil , Water , Water Supply
19.
Environ Geochem Health ; 46(5): 175, 2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38619636

ABSTRACT

Alpine lakes are aquatic ecosystems that maintain and regulate water supply for the downstream streams, rivers, and other reservoirs. This study examined the water characteristics of various alpine lakes in Gilgit-Baltistan, Northern Pakistan. For this purpose, water was sampled and investigated for basic parameters, anions, and cations using the multi-parameter analyzers and atomic absorption spectrophotometer. Physicochemical parameters of alpine lakes were noted under the World Health Organization water guidelines, except for fluoride (F-) and turbidity in 4.3% and 36% of samples, respectively. Water quality index (WQI) classified samples (93%) as excellent and good quality (7%). Results showed maximum chronic daily intake values (0.14 ± 0.01 mg/kg-day) for nitrate (NO3-) and hazard quotient (0.80 ± 0.24) for F- in children via water intake from Upper Kachura and Shausar Lakes, respectively. Statistical analyses of Piper and Gibbs's plots revealed that the water quality is mainly characterized by bedrock geology.


Subject(s)
Ecosystem , Water Quality , Child , Humans , Lakes , Water Supply , Fluorides
20.
J Environ Manage ; 357: 120677, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38565033

ABSTRACT

Attention on the use of transboundary aquifers (TBAs) and their cross-border impacts is growing as countries become increasingly concerned about their long-term water security. Cross-border impacts, in groundwater quality and quantity, tend to concentrate in specific parts of TBAs, as they largely depend on the transboundary flow dynamics where anthropogenic actions operate. Thus, there is a growing consensus that strategies intended to prevent or mitigate such impacts should be implemented in strategic zones rather than in the whole TBA. These transboundary groundwater management zones (TGMZs) are relatively recent but have become a prominent topic in TBA management. However, until now, limited effort has been put into exploring the concept of TGMZs and the methods for their delineation. This research aims to fill these gaps and provide a basis for the delineation of TGMZs, thus helping neighbouring countries meet international responsibilities regarding the right to use and enjoy groundwater in TBAs. By reviewing academic and grey literature accessible from public sources, we present an overview of the concept and terminology of TGMZs, the approaches proposed for their delineation, and current operating examples. Additionally, we build a conceptual framework for assessing cross-border groundwater impacts by identifying their typologies and causal factors. We then apply our framework to evaluate and compare three reported methods which identify and delineate TGMZs from distinct perspectives, thereby gaining insights into their principles, performances, and limitations. Finally, we provide recommendations for further research towards optimising methods for delineating TGMZs.


Subject(s)
Groundwater , Water Pollutants, Chemical , Water Supply , Water Pollutants, Chemical/analysis , Water , Environmental Monitoring/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...